Availability: | |
---|---|
Quantity: | |
BXM-60EI/80EI/110EI
The vertical pressure steam sterilizer uses saturated water vapor to act on the microorganisms on the load for a certain period of time, denaturing the protein of the microorganisms, leading to microbial death, in order to achieve the purpose of sterilization. Suitable for high-pressure steam sterilization of conventional sterilization items such as culture media, medical devices, glassware, containers, waste, etc. It is mainly used in fields such as biomedicine, food, inspection and testing, inspection and quarantine, agriculture, forestry, animal husbandry, fishery, environmental protection, scientific research, etc.
· PMMA I microcomputer intelligent operating system
· Large-size capacitive touch screen enables real-time viewing of the operating parameters and working status diagram of the device during its working phase
· Positive pressure pulse, 6 level cold air discharge procedure can be set to ensure the thorough cold air discharge
· Equipped with 8 fixed programs +6 custom programs
· After sterilization, the 6-stage pressure relief rate is optional
· With three-level authority management of engineer, administrator and operator
· The whole machine anti - hot design, heat insulation and beautiful
· Classic handwheel type door opening structure, with double protection of pressure mechanical self-locking and closed cover self-inspection
· Equipped with 100-hour countdown reservation function
· One key electric drainage, more convenient for operation
· Equipped with boiling point setting function to ensure that the instrument can be heated to the required sterilization temperature at high altitude
· Standard equipped with condenser + air cooling + secondary water cooling rapid cooling system to shorten the waiting time for opening the cover
· One waterproof socket, two 485 ports and G1/2A standard test pipe thread holes
· Fault detection function, overtemperature shutdown protection, water cut-off protection, overpressure self-relief protection, anti-hot protection, overload protection,
· Short circuit protection, leakage protection, independent electronic overvoltage protection and other multiple security
Optional accessories
· Special printer: realize date, time, temperature, sterilization process and curve printing
· Sample temperature probe: realize the printing of F0 value Verify the lead
Operation Panel Schematic diagram of positive pressure pulse
Model | BXM-60EI | BXM-85EI | BXM-110EI |
Volume [L] | 60 | 85 | 110 |
Drum diameter[mm] | 400 | 400 | 400 |
Power Supply [V, Hz] | 220±10%, 50±2% | 220±10%, 50±2% | 220±10%, 50±2% |
Environment Temp. [°C] | 5~40 | 5~40 | 5~40 |
Environment Humidity [%RH] | 20~80 | 20~80 | 20~80 |
Power [kW] | 3.2 | 3.5 | 3.5 |
Sterilization Temp. [°C] | 105~135 | 105~135 | 105~135 |
Temp. fluctuations [°C] | ˂±1 | ˂±1 | ˂±1 |
Temp. Uniformity[°C] | ≦±0.5 | ≦±0.5 | ≦±0.5 |
Melting Temp. [°C] | 50~100 | 50~100 | 50~100 |
Heat Preservation Temp. [°C] | 40-60 | 40-60 | 40-60 |
Sterilization Timer Range [min] | 0-120 | 0-120 | 0-120 |
Melting Timer Range [min] | 0-6000 | 0-6000 | 0-6000 |
Heat Preservation Timer Range [min] | 0-6000 | 0-6000 | 0-6000 |
Reservation Range [min] | 0-6000 | 0-6000 | 0-6000 |
Design Pressure [MPa] | 0.38 | 0.38 | 0.38 |
Working Pressure [MPa] | 0.22 | 0.22 | 0.22 |
Pressure gauge indicating range[MPa] | 0-0.4 | 0-0.4 | 0-0.4 |
Housing Dimensions W×D×H [mm] | 535*640*1075 | 535*640*1165 | 535*640*1275 |
Basket Dimensions [mm] | 370*245 | 370*285 | 370*245 |
Number of Baskets [pc] | 2 | 2 | 3 |
Net weight [kg] | 100 | 105 | 111 |
Gross weight [kg] | 118 | 124 | 130 |
Package size [mm] | 670*780*1240 | 670*780*1330 | 670*780*1440 |
The vertical pressure steam sterilizer uses saturated water vapor to act on the microorganisms on the load for a certain period of time, denaturing the protein of the microorganisms, leading to microbial death, in order to achieve the purpose of sterilization. Suitable for high-pressure steam sterilization of conventional sterilization items such as culture media, medical devices, glassware, containers, waste, etc. It is mainly used in fields such as biomedicine, food, inspection and testing, inspection and quarantine, agriculture, forestry, animal husbandry, fishery, environmental protection, scientific research, etc.
· PMMA I microcomputer intelligent operating system
· Large-size capacitive touch screen enables real-time viewing of the operating parameters and working status diagram of the device during its working phase
· Positive pressure pulse, 6 level cold air discharge procedure can be set to ensure the thorough cold air discharge
· Equipped with 8 fixed programs +6 custom programs
· After sterilization, the 6-stage pressure relief rate is optional
· With three-level authority management of engineer, administrator and operator
· The whole machine anti - hot design, heat insulation and beautiful
· Classic handwheel type door opening structure, with double protection of pressure mechanical self-locking and closed cover self-inspection
· Equipped with 100-hour countdown reservation function
· One key electric drainage, more convenient for operation
· Equipped with boiling point setting function to ensure that the instrument can be heated to the required sterilization temperature at high altitude
· Standard equipped with condenser + air cooling + secondary water cooling rapid cooling system to shorten the waiting time for opening the cover
· One waterproof socket, two 485 ports and G1/2A standard test pipe thread holes
· Fault detection function, overtemperature shutdown protection, water cut-off protection, overpressure self-relief protection, anti-hot protection, overload protection,
· Short circuit protection, leakage protection, independent electronic overvoltage protection and other multiple security
Optional accessories
· Special printer: realize date, time, temperature, sterilization process and curve printing
· Sample temperature probe: realize the printing of F0 value Verify the lead
Operation Panel Schematic diagram of positive pressure pulse
Model | BXM-60EI | BXM-85EI | BXM-110EI |
Volume [L] | 60 | 85 | 110 |
Drum diameter[mm] | 400 | 400 | 400 |
Power Supply [V, Hz] | 220±10%, 50±2% | 220±10%, 50±2% | 220±10%, 50±2% |
Environment Temp. [°C] | 5~40 | 5~40 | 5~40 |
Environment Humidity [%RH] | 20~80 | 20~80 | 20~80 |
Power [kW] | 3.2 | 3.5 | 3.5 |
Sterilization Temp. [°C] | 105~135 | 105~135 | 105~135 |
Temp. fluctuations [°C] | ˂±1 | ˂±1 | ˂±1 |
Temp. Uniformity[°C] | ≦±0.5 | ≦±0.5 | ≦±0.5 |
Melting Temp. [°C] | 50~100 | 50~100 | 50~100 |
Heat Preservation Temp. [°C] | 40-60 | 40-60 | 40-60 |
Sterilization Timer Range [min] | 0-120 | 0-120 | 0-120 |
Melting Timer Range [min] | 0-6000 | 0-6000 | 0-6000 |
Heat Preservation Timer Range [min] | 0-6000 | 0-6000 | 0-6000 |
Reservation Range [min] | 0-6000 | 0-6000 | 0-6000 |
Design Pressure [MPa] | 0.38 | 0.38 | 0.38 |
Working Pressure [MPa] | 0.22 | 0.22 | 0.22 |
Pressure gauge indicating range[MPa] | 0-0.4 | 0-0.4 | 0-0.4 |
Housing Dimensions W×D×H [mm] | 535*640*1075 | 535*640*1165 | 535*640*1275 |
Basket Dimensions [mm] | 370*245 | 370*285 | 370*245 |
Number of Baskets [pc] | 2 | 2 | 3 |
Net weight [kg] | 100 | 105 | 111 |
Gross weight [kg] | 118 | 124 | 130 |
Package size [mm] | 670*780*1240 | 670*780*1330 | 670*780*1440 |